| Script |
X-FOAM is a 100% water-blown environmentally-friendly product that reacting isocyanate and polymer resin with high pressure spray machine
|
| Special feature |
- Environmental product as using water that in zero O.D.P(Ozone Depletion Potential) and G.W.P(Global Warming Potential)
- X-FOAM expands to about 100 times its volume in just seconds and is applied by spraying liquid components onto an open wall,crawl space or ceiling surface
- Good adhesion on any substrate
( On steel, wood, concrete and aluminum etc )
- Excellent sound absorption performance owing to semi-open cell
- Self-extinguishing product
- V.O.C ( Volatile Organic Compounds ) Free |
| Use |
A multistory building, villa, dwelling, hotel, hospital, factory, gym, industrial facilities and stock raising facilities of need to the sound absorption performance and insulation |
| Working Process |
Impurities removal and Surface Treatment => X-FOAM Spray
=> Completion |
| Physical properties |
X-FOAM (A) X-FOAM(B)
VISCOSITY
(@25¡É , cps) 250¡¾50 450¡¾50
DENSITY 11 (Kg/m3)
Thermal Conductivity
(AVE TEMP : 20¡¾5¡É) 0.036 (W/m.k)
Water Absorption 2.7 (g/100cm2)
Flammability No efects
Gas Noxiousness Pass
CFC/HCFC/HFC Zero |
| Application |
RECOMMENDED EQUIPMENT AND SETTINGS
- Physical properties will be enhanced when sprayed at higher pressure ( 1200psi more )
- Pre-heat temperature should be at 60~70¡É before use
- Hose temperature should be at 60~70¡É
EQUIPMENT
- Spray equipment model High pressure airless spray ( DUMA-300 )
- Gun model : PROBLER Gun
- Hose length : 60~90m
Clean up solvent
- DBP , M.C(Methylene Chloride) , E.C (Ethyl Cellosolve) |
| Packing |
2 Drum/kit |
| Warning |
may cause bums to eyes and skin. Potential skin sensitizer. Inhalation of vapor may cause respiratory tract irritation. May be harmful if swallowed or absorbed through the skin. Do not get on skin, in eyes or on clothing. Avoid inhaling vapors.
Do not take internally.
See complete warning on container.
Review material safety data sheet for detailed safety information before use.
For industrial use only. |
| REMARK |
This data sheet can be changed for improving quality of the product without customer's agreement. |